Please use this identifier to cite or link to this item: https://ri-ng.uaq.mx/handle/123456789/1272
Title: Diseño e implementación de un sistema BCI para el análisis de EEG.
metadata.dc.creator: Luz Maria Sanchez Reyes
Keywords: INGENIERÍA Y TECNOLOGÍA
Issue Date: 1-Oct-2017
metadata.dc.degree.department: Facultad de Ingeniería
metadata.dc.degree.name: Ingeniería en Automatización
Description: El propósito de esta investigación es implementar un sistema BCI (Brain Computer Interface) con arquitectura abierta para el an ́alisis de potenciales. Espec ́ıficamente, el proyecto consiste en lograr que la interfaz para mostrar las sen ̃ales EEG (electroencefalograma) pueda ser modificable, as ́ı como la programacio ́n del procesador embebido (DSP, Digital Signal Processor), es decir, tener un sistema de adquisicio ́n de sen ̃ales EEG capaz de ser modificado a como mejor convenga al usuario. Se presentan algunos datos histo ́ricos sobre el desarrollo de los sistemas BCI en las u ́ltimas décadas y la importancia del dispositivo en el ́area de la medicina y ma ́s espec ́ıficamente en la rehabilitacio ́n de personas con discapacidades motrices. Además, se muestran resultados de pruebas EEG a diferentes personas, verificando que los niveles de interferencia y ruido est ́en dentro de los l ́ımites permitidos de acuerdo a otros estudios similares.
The purpose of this research is to implement a BCI (Brain Computer Interface) system with an open architecture for the analysis of potentials. Specifically, the project consists of making the interface to show the EEG (electroencephalogram) signals be modifiable, as well as the programming of the embedded processor (DSP, Digital Signal Processor), that is to say, to have an EEG signal acquisition system capable of being modified to best suit the user. Some historical data on the development of BCI systems in the last decades and the importance of the device in the area of medicine and more specifically in the rehabilitation of people with motor disabilities are presented. Also, results of EEG tests to different people are shown, verifying that the levels of interference and noise are within the allowed limits according to other similar studies.
URI: http://ri-ng.uaq.mx/handle/123456789/1272
Other Identifiers: RI004593
Appears in Collections:Ingeniería en Automatización

Files in This Item:
File Description SizeFormat 
RI004361.pdf6.01 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.