dc.descriptionLas teorías de capacidad de carga para suelos expansivos comúnmente usadas no consideran los efectos de la presión de expansión, dicha fuerza actúa en dirección opuesta a la carga de la edificación, ya que parten de la hipótesis de que el suelo se encuentra completamente saturado. Como consecuencia de esto los diseños de cimentaciones presentan dimensiones sobradas por los bajos valores de capacidad de carga que tiene un suelo en condiciones saturadas. En este trabajo se propone el uso de un parámetro que incluya a la presión de expansión en la ecuación de capacidad de carga de Skempton, considerando que tanto la presión de expansión como la capacidad de carga son variables en función de la humedad, con este nuevo parámetro propuesto se evalúa en que porcentajes aumenta la capacidad de carga y consecuentemente se trabaja con el factor de seguridad para una cimentación con el fin de ver si este también se ve afectado con el parámetro planteado.es_ES
dc.descriptionTheories of bearing capacity for expansive soils commonly used do not consider the effects of expansion pressure, the force acts opposite to the charge of building management, since they start from the assumption that the soil is fully saturated. As a consequence the designs of foundations have ample dimensions for the low values of bearing capacity having a saturated soil conditions. In this paper the use of a parameter including the expansion pressure in the capacity equation is proposed Skempton, considering that both the expansion pressure and bearing capacity are variable according to the moisture, with this new proposed parameter is evaluated in which percentages capacity increases and consequently works with the safety factor for a foundation in order to see whether this is also affected by the proposed parameter.es_ES
dc.formatAdobe PDFes_ES
dc.language.isoEspañoles_ES
dc.relation.requiresSies_ES
dc.rightsAcceso Abiertoes_ES
dc.subjectINGENIERÍA Y TECNOLOGÍAes_ES
dc.subjectCIENCIAS TECNOLÓGICASes_ES
dc.titleEvaluación del impacto de las variaciones de humedad en la expansión y capacidad de carga de un suelo de Juricaes_ES
dc.typeTesis de maestríaes_ES
dc.creator.tidcurpes_ES
dc.contributor.tidcurpes_ES
dc.creator.identificadorCAVA890728HSLSLL07es_ES
dc.contributor.identificadorPERL650926MNTRXZ08es_ES
dc.contributor.roleDirectores_ES
dc.degree.nameMaestría en Ciencias (Construcción)es_ES
dc.degree.departmentFacultad de Ingenieríaes_ES
dc.degree.levelMaestríaes_ES
Appears in Collections:Maestría en Ciencias (Construcción)

Files in This Item:
File Description SizeFormat 
RI003918.pdf1.95 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.