Por favor, use este identificador para citar o enlazar este ítem: https://ri-ng.uaq.mx/handle/123456789/631
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.rights.licensehttp://creativecommons.org/licenses/by-nd/4.0es_ES
dc.contributorRuben Ramirez Jimenezes_ES
dc.creatorRoger Ulisses Hernandez Zamoraes_ES
dc.date2013-09-
dc.date.accessioned2018-12-14T11:59:08Z-
dc.date.available2018-12-14T11:59:08Z-
dc.date.issued2013-09-
dc.identifier.urihttp://ri-ng.uaq.mx/handle/123456789/631-
dc.descriptionLos muros de mampostería son propensos a fallar cuando son sometidos a cargas laterales causadas por sismos o asentamientos diferenciales. Actualmente los polímeros fibro-reforzados (FRP) brindan una solución para contrarrestar dichos efectos, uno de los métodos de refuerzo más utilizados hoy en día es mediante tiras de FRP. El propósito de este trabajo de tesis es evaluar el incremento en la resistencia a cortante en muros de mampostería confinada, al reforzar las diagonales de este utilizando varillas de polímero fibro-reforzado (FRP) sobre las juntas horizontales de mortero. Para tal efecto se ensayaron dos muros de mampostería confinada a escala natural, construidos con piezas de block y mortero tipo I. Uno de los muros se reforzó con varillas de fibra de vidrio (GFRP) colocadas horizontalmente sobre las juntas de mortero y cubrían 0.5 m de cada lado de las diagonales en ambas caras del espécimen, mientras que el otro muro se dejó sin reforzar. Se seleccionó dicha técnica de refuerzo debido a que en estas zonas se genera la mayor concentración de esfuerzos. Se les aplicó carga axial constante simulando las cargas inducidas por una construcción de dos niveles y carga lateral cíclica reversible en su plano. De los resultados se concluye que la carga de agrietamiento fue la misma para los dos muros, sin embargo, el muro reforzado presentó un patrón de agrietamiento distribuido y de ancho menor que el correspondiente al muro sin refuerzo. Además éste exhibió una resistencia última 1.53 veces mayor que la del correspondiente al muro sin refuerzo, se estima que eso fue debido a que el sistema de refuerzo propuesto inhibió el agrietamiento en la diagonal sin necesidad de reforzar completamente todas las juntas de la mampostería.es_ES
dc.descriptionThe masonry walls are prone to failure when subjected to lateral loads caused by earthquakes or differential settlements. Currently, fiber-reinforced polymers (FRP) provide a solution to counteract such effects. One of the most widely used reinforcement methods today is by using FRP strips. The purpose of this thesis is to evaluate the increase in shear resistance of confined masonry walls, to strengthen the diagonals of the rods using Fibro-Reinforced Polymer (FRP) on horizontal mortar joints. For this purpose, two full-scale confined masonry walls built with pieces of block and mortar type I were tested. One of them was reinforced with fiberglass rods (GFRP) placed horizontally on the mortar joints and covered 0.5 m on each side of the diagonals on both sides of the specimen, while the other one did not. This technique was selected because the highest concentration of efforts is generated in these areas. The walls were applied constant axial load simulating loads induced by a two-level construction and a reversible cyclic load in its plane. This experimental data showed that both walls showed the same cracking load, however, the reinforced wall showed better cracking pattern and smaller crack width.The reinforced one supported an ultimate load 1.53 times larger than the unreinforced wall, probably because the proposed reinforcement system inhibited the diagonal cracking without having to fully reinforce all the joints of the masonry.es_ES
dc.formatAdobe PDFes_ES
dc.language.isoEspañoles_ES
dc.relation.requiresSies_ES
dc.rightsAcceso Abiertoes_ES
dc.subjectAgrietamientoses_ES
dc.subjectCrackinges_ES
dc.subjectMamposteríaes_ES
dc.subjectMasonryes_ES
dc.subjectRefuerzoes_ES
dc.subjectReinforcinges_ES
dc.subject.classificationINGENIERÍA Y TECNOLOGÍAes_ES
dc.titleComportamiento de muros de mampostería de block hueco sujeto a cargas laterales, reforzado con varillas de fibra de vidrio en las juntas de morteroes_ES
dc.typeTesis de maestríaes_ES
dc.creator.tidcurpes_ES
dc.contributor.tidcvues_ES
dc.creator.identificadorHEZR871001HSLRMG05es_ES
dc.contributor.identificador0000-0002-2540-0305es_ES
dc.contributor.roleDirectores_ES
dc.degree.nameMaestría en Ciencias (Construcción)es_ES
dc.degree.departmentFacultad de Ingenieríaes_ES
dc.degree.levelMaestríaes_ES
Aparece en: Maestría en Ciencias (Construcción)

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
RI003741.pdf5.1 MBAdobe PDFPortada
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.