Por favor, use este identificador para citar o enlazar este ítem: https://ri-ng.uaq.mx/handle/123456789/245
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.rights.licensehttp://creativecommons.org/licenses/by-nd/4.0es_ES
dc.contributorSantiago Andaracua Garciaes_ES
dc.creatorBianca Jimena Lozano Quezadaes_ES
dc.date2016-10-
dc.date.accessioned2018-12-06T15:52:50Z-
dc.date.available2018-12-06T15:52:50Z-
dc.date.issued2016-10-
dc.identifier.urihttp://ri-ng.uaq.mx/handle/123456789/245-
dc.descriptionLimpiar y conformar el sistema de conductos radiculares es una parte extremadamente importante durante el tratamiento de Endodoncia, los instrumentos de Níquel Titanio ofrecen mayor flexibilidad, siendo esta superelasticidad con la que cuentan lo que permite mejorar la conformación y evitar transportaciones de la trayectoria original del conducto radicular; Sin embargo, fracturas de limas dentro del conducto radicular son aún comunes con instrumentos de Níquel Titanio, comprometiendo de manera significativa el tratamiento de Endodoncia. Sattapan y col. reportan una frecuencia del 21% en la incidencia de fracturas dentro del conducto radicular, es por eso que el estudio de los mecanismos de separación de las limas es muy importante para lograr disminuir las probabilidades de que esto ocurra.El objetivo general de esta investigación fue determinar el desgaste por pérdida de masa en limas endodónticas de Níquel Titanio utilizando Microdacyn 60® versus NaOCl al 5.25% para su desinfección. Este estudio fue de tipo observacional y comparativo; llevándose a cabo mediante una muestra de 10 limas endodónticas de Níquel Titanio: 2 limas SM3 TF Adaptive ® nuevas, 2 limas SM3 TF Adaptive ® con 2 usos en molares, 2 limas SM3 TF Adaptive ® con 4 usos en molares, 2 limas K3XF ® nuevas, 1 lima Hyflex ® nueva y 1 lima White ® nueva. Para determinar su masa inicial, se realizó el pesaje de cada lima en el Laboratorio Q-20 con la Microbalanza Mettler XP6 en el Centro Nacional de Metrología, y se observaron bajo Microscopio Electrónico de Barrido antes y después de la exposición a las sustancias desinfectantes. Se comprobó la hipótesis nula al no haber diferencia en el desgaste por la pérdida de masa de limas Ni-Ti al utilizar Microdacyn 60® e NaOCl al 5.25% para su desinfección. Sin embargo, bajo el SEM se observaron los inicios de cambios en la estructura de las limas, comprobando que el NaOCl al 5.25% tiene mayor efecto corrosivo que el Microdacyn 60® durante la fase de desinfección.es_ES
dc.descriptionCleaning and shapping the root canal is an extremely important part of the endodontic treatment, nickel titanium instruments offer greater flexibility, and have super-elasticity which improves the formation and avoid transportations, maintaining the original root canal configuration . However, fractures files into the root canal are still common with NITI instruments, compromising the endodontic treatment. Sattapan et al. reported 21% in the incidence of fractures within the root canal, so studding mechanisms of separation of files is very important to reduce the chances of this happening.The aim objective of this research was to determine the mass loss in NI-TI endodontic files using NaOCl 5.25 % versus Mycrodacyn 60® for disinfection. This study was observational and comparative type; a sample of 10 endodontic files nickel titanium: 2 new files Sm3 TF Adaptive ®, 2 files Sm3 TF Adaptive ® that has been used twice, 2 files Sm3 TF Adaptive ® that has been used 4 times, 2 new files K3XF ®, 1 new file Hyflex ®, 1 new file White ®. To determine its initial mass, weighing each file was performed at the Laboratory Q-20. With Mettler XP6 microbalance at the National Centre of Metrology, and observed under scanning electron microscope before and after exposure to disinfectants. The null hypothesis shows to be no difference in the mass loss of Ni-Ti files using NaOCl 5.25 % versus Mycrodacyn 60 ® for disinfection. However under SEM the early changes seen in the structure of the files, revealed that NaOCl 5.25 % has more corrosive effect than Microdacyn 60 ® during the disinfection phase.es_ES
dc.formatAdobe PDFes_ES
dc.language.isoEspañoles_ES
dc.relation.requiresSies_ES
dc.rightsAcceso Abiertoes_ES
dc.subjectEndodontic files fracturees_ES
dc.subjectFractura de limas endodónticases_ES
dc.subjectMass losses_ES
dc.subjectNaOCles_ES
dc.subjectNickees_ES
dc.subjectTitaniumes_ES
dc.subjectPérdida de masaes_ES
dc.subject.classificationMEDICINA Y CIENCIAS DE LA SALUDes_ES
dc.titleEvaluación del desgaste de limas endodónticas de Níquel Titanio utilizando Microdacyn 60® versus NaOCl al 5.25% para la desinfección por medio de pérdida de masaes_ES
dc.typeother-
dc.typeacademicSpecialization-
dc.creator.tidcurpes_ES
dc.contributor.tidcurpes_ES
dc.creator.identificadorLOQB871019MSPZZN06es_ES
dc.contributor.identificadorAAGS830725HGTNRN02es_ES
dc.contributor.roleDirectores_ES
dc.degree.nameEspecialidad en Endodonciaes_ES
dc.degree.departmentFacultad de Medicinaes_ES
dc.degree.levelEspecialidades_ES
Aparece en: Especialidad en Endodoncia

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
RI003363.pdf6.5 MBAdobe PDFPortada
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.