Por favor, use este identificador para citar o enlazar este ítem:
https://ri-ng.uaq.mx/handle/123456789/245
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.rights.license | http://creativecommons.org/licenses/by-nd/4.0 | es_ES |
dc.contributor | Santiago Andaracua Garcia | es_ES |
dc.creator | Bianca Jimena Lozano Quezada | es_ES |
dc.date | 2016-10 | - |
dc.date.accessioned | 2018-12-06T15:52:50Z | - |
dc.date.available | 2018-12-06T15:52:50Z | - |
dc.date.issued | 2016-10 | - |
dc.identifier.uri | http://ri-ng.uaq.mx/handle/123456789/245 | - |
dc.description | Limpiar y conformar el sistema de conductos radiculares es una parte extremadamente importante durante el tratamiento de Endodoncia, los instrumentos de Níquel Titanio ofrecen mayor flexibilidad, siendo esta superelasticidad con la que cuentan lo que permite mejorar la conformación y evitar transportaciones de la trayectoria original del conducto radicular; Sin embargo, fracturas de limas dentro del conducto radicular son aún comunes con instrumentos de Níquel Titanio, comprometiendo de manera significativa el tratamiento de Endodoncia. Sattapan y col. reportan una frecuencia del 21% en la incidencia de fracturas dentro del conducto radicular, es por eso que el estudio de los mecanismos de separación de las limas es muy importante para lograr disminuir las probabilidades de que esto ocurra.El objetivo general de esta investigación fue determinar el desgaste por pérdida de masa en limas endodónticas de Níquel Titanio utilizando Microdacyn 60® versus NaOCl al 5.25% para su desinfección. Este estudio fue de tipo observacional y comparativo; llevándose a cabo mediante una muestra de 10 limas endodónticas de Níquel Titanio: 2 limas SM3 TF Adaptive ® nuevas, 2 limas SM3 TF Adaptive ® con 2 usos en molares, 2 limas SM3 TF Adaptive ® con 4 usos en molares, 2 limas K3XF ® nuevas, 1 lima Hyflex ® nueva y 1 lima White ® nueva. Para determinar su masa inicial, se realizó el pesaje de cada lima en el Laboratorio Q-20 con la Microbalanza Mettler XP6 en el Centro Nacional de Metrología, y se observaron bajo Microscopio Electrónico de Barrido antes y después de la exposición a las sustancias desinfectantes. Se comprobó la hipótesis nula al no haber diferencia en el desgaste por la pérdida de masa de limas Ni-Ti al utilizar Microdacyn 60® e NaOCl al 5.25% para su desinfección. Sin embargo, bajo el SEM se observaron los inicios de cambios en la estructura de las limas, comprobando que el NaOCl al 5.25% tiene mayor efecto corrosivo que el Microdacyn 60® durante la fase de desinfección. | es_ES |
dc.description | Cleaning and shapping the root canal is an extremely important part of the endodontic treatment, nickel titanium instruments offer greater flexibility, and have super-elasticity which improves the formation and avoid transportations, maintaining the original root canal configuration . However, fractures files into the root canal are still common with NITI instruments, compromising the endodontic treatment. Sattapan et al. reported 21% in the incidence of fractures within the root canal, so studding mechanisms of separation of files is very important to reduce the chances of this happening.The aim objective of this research was to determine the mass loss in NI-TI endodontic files using NaOCl 5.25 % versus Mycrodacyn 60® for disinfection. This study was observational and comparative type; a sample of 10 endodontic files nickel titanium: 2 new files Sm3 TF Adaptive ®, 2 files Sm3 TF Adaptive ® that has been used twice, 2 files Sm3 TF Adaptive ® that has been used 4 times, 2 new files K3XF ®, 1 new file Hyflex ®, 1 new file White ®. To determine its initial mass, weighing each file was performed at the Laboratory Q-20. With Mettler XP6 microbalance at the National Centre of Metrology, and observed under scanning electron microscope before and after exposure to disinfectants. The null hypothesis shows to be no difference in the mass loss of Ni-Ti files using NaOCl 5.25 % versus Mycrodacyn 60 ® for disinfection. However under SEM the early changes seen in the structure of the files, revealed that NaOCl 5.25 % has more corrosive effect than Microdacyn 60 ® during the disinfection phase. | es_ES |
dc.format | Adobe PDF | es_ES |
dc.language.iso | Español | es_ES |
dc.relation.requires | Si | es_ES |
dc.rights | Acceso Abierto | es_ES |
dc.subject | Endodontic files fracture | es_ES |
dc.subject | Fractura de limas endodónticas | es_ES |
dc.subject | Mass loss | es_ES |
dc.subject | NaOCl | es_ES |
dc.subject | Nicke | es_ES |
dc.subject | Titanium | es_ES |
dc.subject | Pérdida de masa | es_ES |
dc.subject.classification | MEDICINA Y CIENCIAS DE LA SALUD | es_ES |
dc.title | Evaluación del desgaste de limas endodónticas de Níquel Titanio utilizando Microdacyn 60® versus NaOCl al 5.25% para la desinfección por medio de pérdida de masa | es_ES |
dc.type | other | - |
dc.type | academicSpecialization | - |
dc.creator.tid | curp | es_ES |
dc.contributor.tid | curp | es_ES |
dc.creator.identificador | LOQB871019MSPZZN06 | es_ES |
dc.contributor.identificador | AAGS830725HGTNRN02 | es_ES |
dc.contributor.role | Director | es_ES |
dc.degree.name | Especialidad en Endodoncia | es_ES |
dc.degree.department | Facultad de Medicina | es_ES |
dc.degree.level | Especialidad | es_ES |
Aparece en: | Especialidad en Endodoncia |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
RI003363.pdf | 6.5 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.