Por favor, use este identificador para citar o enlazar este ítem: https://ri-ng.uaq.mx/handle/123456789/1449
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.rights.licensehttp://creativecommons.org/licenses/by-nc/4.0es_ES
dc.contributorAnelisse Yerett Oliveri Riveraes_ES
dc.creatorJuana Guadalupe Herrera Perezes_ES
dc.date2019-01-07-
dc.date.accessioned2019-05-13T21:05:28Z-
dc.date.available2019-05-13T21:05:28Z-
dc.date.issued2019-01-07-
dc.identifierFatigaes_ES
dc.identifierSomnolenciaes_ES
dc.identifierSistema de asistenciaes_ES
dc.identifierEstado de alertaes_ES
dc.identifierFatiguees_ES
dc.identifierDrowsinesses_ES
dc.identifierAssistance systemes_ES
dc.identifierAlertnesses_ES
dc.identifier.urihttp://ri-ng.uaq.mx/handle/123456789/1449-
dc.descriptionDiversos factores como el incremento en la demanda de productos y servicios durante las 24 horas del día, ha fomentado la sobre exigencia física, haciendo que los horarios laborales aumenten, generando nuevos problemas y necesidades a resolver. Tal es el caso de la aparición de periodos de somnolencia durante las jornadas laborales, lo cual se ha convertido en una causa importante de accidentes automovilísticos, industriales y médicos. La somnolencia es causada por el ritmo circadiano y la privación del sueño, es un estado fisiológico donde el tiempo de respuesta es más lento que los niveles normales, los principales síntomas de somnolencia son la falta de capacidad de concentración, atención, vigilancia y dificultades para mantenerse despierto (Abbood, et al., 2014). En esta tesis se presenta el desarrollo de un sistema de asistencia no intrusivo para la detección de somnolencia en tiempo real, que alerta al usuario si es necesario, con el objetivo de reducir el número de accidentes causados por somnolencia. El dispositivo desarrollado está basado en el monitoreo de ritmo cardiaco debido a que el sistema nervioso autónomo afecta el latido del corazón de una persona con somnolencia (Bader, 2002). En este proyecto se realizaron estudios aplicando la metodología seis sigma para el desarrollo de productos, basándose en una muestra de 20 usuarios, monitoreando su ritmo cardiaco a lo largo de sus actividades diarias para determinar sus rangos de vigilia y sueño, posteriormente se realizaron pruebas con un simulador de manejo activando un sistema de asistencia cuando su estado de alerta disminuía drásticamente. Como sistema de asistencia se incorporó una alarma sonora para recuperar el estado de alerta del usuario, debido a los efectos del sonido en las primeras etapas del sueño. Se identificaron variaciones importantes en el ritmo cardiaco que pueden ser utilizadas para la estandarización del monitoreo de somnolencia, manteniendo la medición del estado de alerta, sin importar los rangos de ritmo cardiaco de cada persona.es_ES
dc.descriptionSeveral factors, such as the increase in the demand for products and services during the 24 hours a day, have encouraged physical over exigency, causing work schedules to increase, generating new problems and needs to be solved. Such is the case of the appearance of periods of drowsiness during working hours, which has become an important cause of automobile, industrial and medical accidents. Drowsiness is caused by the circadian rhythm and sleep deprivation, it is a physiological state where the response time is slower than the normal levels, the main symptoms of drowsiness are the lack of concentration, attention, vigilance and difficulties for stay awake (Abbood, et al., 2014). This thesis presents the development of a non-intrusive assistance system for the detection of drowsiness in real time, which alerts the user if necessary, with the aim of reducing the number of accidents caused by drowsiness. The device developed is based on the monitoring of heart rate because the autonomic nervous system affects the heartbeat of a person with drowsiness (Bader, 2002). In this project, studies were carried out applying the six sigma methodology for the development of products, based on a sample of 20 users, monitoring their heart rate throughout their daily activities to determine their waking and sleep ranges, later tests were performed with a driver simulator by activating an assistance system when his alertness decreased drastically. As an assistance system, an audible alarm was included to recover the user's alert status due to the effects of sound in the early stages of sleep. Important variations in cardiac rhythm were identified that can be used for the standardization of drowsiness monitoring, maintaining the measurement of alertness, regardless of the heart rate ranges of each person.es_ES
dc.formatAdobe PDFes_ES
dc.language.isoEspañoles_ES
dc.relation.requiresSies_ES
dc.rightsEn Embargoes_ES
dc.subjectINGENIERÍA Y TECNOLOGÍAes_ES
dc.subjectCIENCIAS TECNOLÓGICASes_ES
dc.titleSistema de asistencia para el monitoreo de somnolenciaes_ES
dc.typeTesis de maestríaes_ES
dc.creator.tidcurpes_ES
dc.contributor.tidcurpes_ES
dc.creator.identificadorHEPJ890315MDFRRN00es_ES
dc.contributor.identificadorOIRA880401MQTLVN00es_ES
dc.contributor.roleAsesor de tesises_ES
dc.degree.nameMaestría en Diseño e Innovaciónes_ES
dc.degree.departmentFacultad de Ingenieríaes_ES
dc.degree.levelMaestríaes_ES
Aparece en las colecciones: Maestría en Diseño e Innovación

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
RI004523.pdf3.93 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.