Por favor, use este identificador para citar o enlazar este ítem:
https://ri-ng.uaq.mx/handle/123456789/1154
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.rights.license | http://creativecommons.org/licenses/by-nc/4.0 | es_ES |
dc.contributor | Juvenal Rodríguez Reséndiz | es_ES |
dc.creator | Alonso Alejandro Jimenez Garibay | es_ES |
dc.date | 2017-10 | - |
dc.date.accessioned | 2019-02-19T17:46:25Z | - |
dc.date.available | 2019-02-19T17:46:25Z | - |
dc.date.issued | 2017-10 | - |
dc.identifier | Sistema de conversión de energía eólica | es_ES |
dc.identifier | Generador de inducción doblemente alimentado | es_ES |
dc.identifier | Corriente de rotor | es_ES |
dc.identifier | Condición de falla | es_ES |
dc.identifier | Caída de voltaje simétrica y/o asimétrica | es_ES |
dc.identifier | Wind energy conversion system | es_ES |
dc.identifier | Doubly fed induction generator | es_ES |
dc.identifier | Rotor current | es_ES |
dc.identifier | Fault condition Symmetrical and/or asymmetrical voltage drop | es_ES |
dc.identifier.uri | http://ri-ng.uaq.mx/handle/123456789/1154 | - |
dc.description | El modo de condición de operación causado por perturbaciones de voltaje en sistemas de conversión de energía basados en generadores de inducción doblemente alimentados, han traído grandes retos en lo referente a eficiencia y confiabilidad. Esta tesis analiza el impacto de las perturbaciones de voltaje en las corrientes del rotor del generador ante caídas de 50, 80 y 100%, además, describe un procedimiento metodológico para obtener los modelos matemáticos de las corrientes de rotor, que permita aproximar su comportamiento ante condiciones de fallas de voltaje simétricas y asimétricas. Los resultados de los modelos matemáticos propuestos se comparan con simulaciones en el dominio del tiempo ejecutadas en SIMULINK de MATLAB con aproximadamente 95 % de similitud en condiciones de falla simétrica a tierra y 85 % de similitud en condiciones de falla asimétrica a tierra. | es_ES |
dc.description | Operation condition mode caused by voltage disturbances in wind energy conversion systems based on double fed induction generators, have brought great challenges regarding efficiency and reliability. This thesis shows the impact of the rotor currents under 50, 80, and 100 % voltage drop, in addition, describes an analysis methodology to obtain the rotor current models. The main focus of the research is approximate their behavior under symmetrical and asymmetrical fault conditions. The results of the proposed models are compared to MATLABSIMULINK time domain simulations with approximately 95% similarity to a symmetrical voltage drop and 85 % to asymmetrical voltage drop condition. | es_ES |
dc.format | Adobe PDF | es_ES |
dc.language.iso | Español | es_ES |
dc.relation.requires | Si | es_ES |
dc.rights | Acceso Abierto | es_ES |
dc.subject | INGENIERÍA Y TECNOLOGÍA | es_ES |
dc.subject | CIENCIAS TECNOLÓGICAS | es_ES |
dc.title | Mejora la autonomía de sistemas e ólicos ante perturbaciones de voltaje de red mediante un modelo de referencia de corriente-rotor. | es_ES |
dc.type | Tesis de maestría | es_ES |
dc.creator.tid | curp | es_ES |
dc.contributor.tid | curp | es_ES |
dc.creator.identificador | JIGA790314HGTMRL09 | es_ES |
dc.contributor.identificador | RORJ840929HQTDSV02 | es_ES |
dc.contributor.role | Director | es_ES |
dc.degree.name | Doctorado en Ingeniería | es_ES |
dc.degree.department | Facultad de Ingeniería | es_ES |
dc.degree.level | Doctorado | es_ES |
Aparece en las colecciones: | Doctorado en Ingeniería |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
RI004247.pdf | 3.1 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.