Buscar


Mostrar el registro sencillo del ítem

dc.rights.license http://creativecommons.org/licenses/by-nc-nd/4.0 es_ES
dc.contributor Vanessa Vallejo Becerra es_ES
dc.creator Yolanda Jesus Martinez Pimentel es_ES
dc.date 2017-01
dc.date.accessioned 2018-12-14T04:48:14Z
dc.date.available 2018-12-14T04:48:14Z
dc.date.issued 2017-01
dc.identifier.uri http://ri-ng.uaq.mx/handle/123456789/508
dc.description En la actualidad el estudio de neurotransmisores se ha vuelto de gran importancia en el área científica, principalmente médica y farmacológica, debido a que desempeñan un papel importante en el funcionamiento del sistema nervioso central, cardiovascular, renal y hormonal. El estudio de diferentes neurotransmisores, como dopamina (DA), adrenalina (AD), noradrenalina (NE) y/o serotonina (5-HT), radica en poder detectar a tiempo, de acuerdo a sus concentraciones, la aparición de diferentes enfermedades neurodegenerativas como esquizofrenia, epilepsia, trastorno hiperactivo, déficit de atención, depresión, entre otras. En este trabajo se realizó la determinación de diferentes concentraciones de dopamina y serotonina utilizando, como electrolito de apoyo para experimentos voltamperométricos, una solución buffer de fosfatos (PBS) a pH 7.0. La determinación de los neurotransmisores se realizó por un método electroquímico utilizando electrodos modificados en su superficie por materiales nanopartículados de NiAl hidróxidos dobles lamiares (LDH) y de PdNiO, con la finalidad de mejorar propiedades físicas y químicas de la superficie del electrodo de carbón vítreo. Se obtuvieron los perfiles electroquímicos, utilizando una celda convencional de tres electrodos, de cada material por medio de voltamperometría cíclica (CV) y voltamperometría de pulso diferencial (DPV) a diferentes concentraciones de dopamina y serotonina, así como las curvas de calibración para cada neurotransmisor. Una vez realizada la comparación de los materiales electroquímicamente se optó por el material NiAl / LDH ya que presento una mejor sensibilidad en la detección de DA y 5-HT. El material NiAl / LDH fue caracterizado fisicoquímicamente por microscopía electrónica de barrido (SEM), difracción de rayos-X (XRD) y fluorescencia de rayos X (XRF). El desarrollo del dispositivo electroquímico se realizó en base a electrodos serigrafiados de carbono, modificados con el material seleccionado. Se obtuvieron curvas de calibración y con los datos arrojados se realizó la programación de un dispositivo electrónico capaz de detectar concentraciones de serotonina y/o dopamina en una solución buffer fosfatos (PBS) pH 7.0 basados en los niveles encontrados en orina real (0.003mM de DA y 0.001mM de 5-HT), y de esta manera diagnosticar si los niveles son altos, bajos o normales. Los resultados obtenidos de la integración del dispositivo servirán como base para el desarrollo de sensores electroquímicos en condiciones reales altamente sensibles que puedan realizar la detección de de estos neurotransmisores en la orina y realizar diagnósticos oportunos en enfermedades neurodegenerativas. es_ES
dc.description Nowadays the study of neurotransmitters has gained great importance in the scientific area, mainly in medical and pharmacological fields, because they play an important role in the performance of central nervous system, cardiovascular, renal and hormonal. The study of different neurotransmitters, such as dopamine (AD), adrenaline (AD), noradrenaline (NE) and / or serotonin (5-HT), lies in being able to detect on time, according to their concentrations, the appearance of different Neurodegenerative disorders and diseases such as schizophrenia, epilepsy, attention deficit, hyperactivity, depression, among others. In this work the determination of different concentrations of dopamine and serotonin, as a support electrolyte for voltammetric experiments was carried out using a phosphate buffer solution (PBS) at pH 7.0. The determination of the neurotransmitters is performed by electrodes modified on its surface by nanoparticles of NiAl double lamellar hydroxides (LDH) and PdNiO, in order to improve the physical and chemical properties of the surface of the vitreous carbon electrode. Electrochemical profiles were obtained using a conventional three-electrode cell of each material by means of cyclic voltammetry (CV) and differential pulse voltammetry (DPV) at different concentrations of dopamine and serotonin, and obtaining calibration curves for each Neurotransmitter. Once the comparison of the materials was done electrochemically the LDH material was chosen because it presented a better sensitivity in the detection of DA and 5-HT. The LDH material was characterized physicochemically by scanning electron microscopy (SEM), Xray diffraction (XRD) and X-ray fluorescence (XRF). The development of the electrochemical device was based on screen-printed carbon electrodes, modified with the selected material. Calibration curves were obtained and with the data set, an electronic device capable of detecting serotonin and / or dopamine concentrations in a pH 7.0 buffered phosphate solution (PBS) was performed based on the levels found in real urine (0.003mM of DA and 0.001mM 5-HT), and in this way to diagnose if the levels are high, low or normal. The integration of the electronic device plus the obtained results from the would serve as a basis for the development of electrochemical sensors for real conditions to perform the detection of these neurotransmitters in the urine and make timely diagnoses in neurodegenerative diseases. es_ES
dc.format Adobe PDF es_ES
dc.language.iso Español es_ES
dc.relation.requires Si es_ES
dc.rights Acceso Abierto es_ES
dc.subject Dopamina es_ES
dc.subject Dopamine es_ES
dc.subject NiAl/LDH es_ES
dc.subject NiAl/LDH es_ES
dc.subject Serotonin|Serotonina es_ES
dc.subject.classification INGENIERÍA Y TECNOLOGÍA es_ES
dc.title Diseño de un dispositivo electroquímico para la detección de Serotonina y Dopamina es_ES
dc.type Tesis de maestría es_ES
dc.creator.tid curp es_ES
dc.contributor.tid curp es_ES
dc.creator.identificador MAPY911024MMNRML07 es_ES
dc.contributor.identificador VABV800417MDFLCN00 es_ES
dc.contributor.role Asesor de tesis es_ES
dc.degree.name Maestría en Ciencias (Nanotecnología) es_ES
dc.degree.department Facultad de Ingeniería es_ES
dc.degree.level Maestría es_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem