Buscar


Mostrar el registro sencillo del ítem

dc.rights.license http://creativecommons.org/licenses/by-nd/4.0 es_ES
dc.contributor Santiago Andaracua Garcia es_ES
dc.creator Alba Belen Peguero Araiza es_ES
dc.date 2017-03
dc.date.accessioned 2018-12-06T14:56:37Z
dc.date.available 2018-12-06T14:56:37Z
dc.date.issued 2017-03
dc.identifier.uri http://ri-ng.uaq.mx/handle/123456789/241
dc.description La combinación del NaOCl al 1.25% a 60°C y EDTA al 17% como protocolo final de irrigación reportó resultados excelentes para la remoción del lodillo dentinario en todos los tercios del conducto. Durante la instrumentación en el tratamiento endodóntico se forma lodillo dentinario, debido a que la anatomía de los conductos radiculares es irregular, la eliminación de este no puede realizarse óptimamente. El protocolo de irrigación actualmente usado es el de NaOCl al 5.25% en combinación con EDTA a 17%, sin embargo, se ha demostrado que sólo es eficaz en los tercios coronal y medio pero no en apical. Esto puede atribuirse a su alta viscosidad, la cual puede disminuirse al calentar NaOCl a bajas concentraciones. El objetivo del estudio fue determinar la influencia de la temperatura del NaOCl a diferentes concentraciones combinado con EDTA a 17% en la eficacia para LA remoción de lodillo dentinario. El estudio experimental in vitro fue realizado en las instalaciones del Posgrado en Endodoncia de la Facultad de Medicina de la Universidad Autónoma de Querétaro, en 21 premolares inferiores unir radiculares humanos extraídos por razones ortodónticas, los cuales fueron distribuidos aleatoriamente en 7 grupos y conservados en un ambiente húmedo. Se les eliminó la porción coronal para estandarizarlos a 15 mm, posteriormente se instrumentaron con sistema Reciproc® y se aplicaron los protocolos de irrigación dependiendo el grupo: P1: NaOCl al 1.25% a 60°C, P2: NaOCl AL 1.25% a 45°C, P3: NaOCl AL 3% a 45°C, P4: NaOCl AL 3% a 60°C, P5: NaOCl AL 5.25% a 60°C, P6: NaOCl AL 5.25% a 45°C y P7 (GRUPO control): NaOCl AL 5.25% a 25°C. Se dividió la muestra en dos partes iguales para ser examinadas en Microscopía Electrónica de Barrido. Se capturaron micrografías de tres zonas al azar de cada tercio y así registrar los resultados para cada grupo, en donde se evaluaron: Grado1: poca, Grado 2: moderada y Grado 3: abundante concentración de lodillo dentinario. Se aplicó la prueba estadística Kruskal¿Wallis y Poshoc de Dunn. La significancia estadística fue de p> 0.05 al comparar todos los protocolos y de p< 0.05 entre algunos protocolos dentro de los tres tercios. K ¿ 0.80 para todos los protocolos y en todas las mediciones. Los resultados indicaron que el protocolo 1 conformado por NaOCl al 1.25% a 60°C y EDTA al 17% fue el más efectivo. Estos resultados, coinciden con Xiangjun Guo et al. en donde demostró que a menor concentración del NaOCl y a 60°C combinado con EDTA al 17%, es el protocolo ideal para la remoción de lodillo dentinario. En cuanto a la menor efectividad fue registrada para el protocolo 7. es_ES
dc.description The combination of NaOCl at 1.25% at 60 ° C and EDTA at 17% as the final irrigation protocol reported excellent results for removal of the smear layer in all thirds of the canal. During the instrumentation in the endodontic treatment is formed smear layer. Because the root canal anatomy is irregular, the removal of the smear layer cannot be remove optimally. The irrigation protocol currently used is 5.25% NaOCl in combination with EDTA at 17% has been shown to be effective only in the coronal and middle thirds but not in the apical third. This can be attributed to its high viscosity, which can be lowered by heating NaOCl at low concentrations. The objective of the study was to determine the influence of NaOCl temperature at different concentrations combined with 17% EDTA in the efficiency for removal smear layer. This experimental in vitro study was realized in the Postgraduate in Endodontics of the Faculty of Medicine of the Autonomous University of Querétaro, in 21 human inferior premolars extracted for orthodontic reasons. They were randomly distributed in 7 groups and preserved in a humid environment. The crown was removed to standardize them to 15 mm. P1: NaOCl at 1.25% at 60 ° C, P2: NaOCl 1.25% at 45 ° C, P3: NaOCl 3% at 45 ° C, P4: NaOCl 3% at 60 ° C, P5: NaOCl 5.25% at 60 ° C, P6: NaOCl 5.25% at 45 ° C and P7 (control): NaOCl 5.25% at 25 ° C. The sample was divided in two equal halves and examined in Scanning Electron Microscopy. Three micrographs were taken at random from each third. Results were recorded for each group, where they were evaluated: Grade 1: low, Grade 2: moderate and Grade 3: abundant concentration of smear layer. Statistical test Kruskal - Wallis and Poshoc Dunn were applied. The statistical significance was p> 0.05 when comparing all protocols and p <0.05 between some protocols within three thirds. K ¿ 0.80 for all protocols and for all measurements. The results indicated that protocol 1 who consist in the combination of NaOCl at 1.25% at 60 ° C and EDTA at 17% was the most effective for removal smear layer in all thirds. These results agree with the study of Xiangjun Guo et al., where it showed that at a lower concentration of NaOCl and at 60 ° C combined with EDTA at 17%, is the ideal protocol for the removal of smear layer. The lowest effectiveness was recorded for protocol 7. es_ES
dc.format Adobe PDF es_ES
dc.language.iso Español es_ES
dc.relation.requires Si es_ES
dc.rights Acceso Abierto es_ES
dc.subject Concentración es_ES
dc.subject Concentration es_ES
dc.subject Lodillo dentinario es_ES
dc.subject NaOCl es_ES
dc.subject NaOCl es_ES
dc.subject Smear layer es_ES
dc.subject.classification MEDICINA Y CIENCIAS DE LA SALUD es_ES
dc.title Determinación de la influencia de la temperatura del NaOCL a diferentes concentraciones combinado EDTA a 17% en la eficacia para la remoción de lodillo dentinario. Estudio en vitro es_ES
dc.type other
dc.type academicSpecialization
dc.creator.tid curp es_ES
dc.contributor.tid curp es_ES
dc.creator.identificador PEAA890920MGTGRL03 es_ES
dc.contributor.identificador AAGS830725HGTNRN02 es_ES
dc.contributor.role Director es_ES
dc.degree.name Especialidad en Endodoncia es_ES
dc.degree.department Facultad de Medicina es_ES
dc.degree.level Especialidad es_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem