Mostrar el registro sencillo del ítem
dc.rights.license | http://creativecommons.org/licenses/by-nc-sa/4.0 | es_ES |
dc.contributor | Oscar Gabriel Lozano Torres | es_ES |
dc.creator | Jhonatan Salinas Ortiz | es_ES |
dc.date | 2018-03 | |
dc.date.accessioned | 2019-03-04T16:34:28Z | |
dc.date.available | 2019-03-04T16:34:28Z | |
dc.date.issued | 2018-03 | |
dc.identifier.uri | http://ri-ng.uaq.mx/handle/123456789/1296 | |
dc.description | La presente investigación evaluó la distribución del estrés en cada uno de los órganos dentarios superiores e inferiores, en los vectores de dirección más utilizados durante los movimientos ortodóncicos, torque, tipping, traslación, rotación, intrusión y extrusión a través del método de elementos finitos. Se modelaron cada uno de los órganos dentarios a través del programa Inventor Professional 2016, una vez obtenidos los modelos 3Dse les introdujeron las propiedades de módulo de Young y coeficiente de Poisson a cada uno de los principales elementos que conforman la estructura dental y periodontal, esmalte, dentina, cemento, ligamento periodontal y hueso alveolar con el objetivo de que los modelos 3D reaccionen lo más cercano posible al ambiente real. Despuésse transfirieron al programa ANSYS Workbench para realizar la simulación, a cada uno de los órganos dentarios se les aplico el rango de fuerzas óptimas propuestas por Proffit et al (2013) para cada una de las direcciones expuestas anteriormente con el objetivo de observar la distribución del estrés y la tensión de Von Misses, es decir, si existe un punto crítico que pueda desencadenar en una resorción irreversible tanto radicular como ósea con el fin de conocer si el rango de fuerzas utilizado mayormentees el óptimo. Como resultado se obtuvo que el rango de fuerzas utilizado para las direcciones de torque, tipping, traslación y extrusión generan un estrés muy crítico por lo que se decidió cambiar el rango de fuerza máximo para estos movimientos.Tambiénse modelaron brackets con la prescripción de la filosofía Alexander y MBT para comparar el estrés generado por ambas prescripciones y la diferencia entre el slot .018 y .022, encontrando que ambas prescripciones generan la misma cantidad de estrés,aunque en dientes diferentes. | es_ES |
dc.description | The present investigation evaluated the distribution of stress in each of the upper and lower dental organs, in the mostused vectors of direction during orthodontic movements, torque, tipping, translation, rotation, intrutsion and extrusion through the finite element method. Each of the dental organs was modeled through the Inventor Professional 2016 program. Once the 3D models were obtained, the properties of Young's modulus and Poisson's coefficient were introduced to each of the main elements that make up the dental and periodontal structure, enamel, dentine, cement, periodontal ligament and alveolar bone with the aim that the 3D models react as close as possible to the real environment. After they were transferred to the ANSYS Workbench program to perform the simulation, each one of the dental organs was applied the range of optimal forces proposed by Proffit et al (2013) for each of the directions previously exposed with the objective of observing the distribution of stress and tension of Von Misses, that is, if there is a critical point that can trigger an irreversible resorption both root and bone in order to know if the range of forces used is the optimum.As a result, it was obtained that the range of forces used for torque, tipping, translation and extrusion directions generate a very critical stress, so it was decided to change the maximum force range for these movements.Brackets were also modeled with the prescription of the Alexander and MBT philosophy to compare the stress generated by both prescriptions and the difference between slot .018 and .022, finding that both prescriptions generate the same amount of stress, although in different teeth. | es_ES |
dc.format | Adobe PDF | es_ES |
dc.language.iso | Español | es_ES |
dc.relation.requires | Si | es_ES |
dc.rights | Acceso Abierto | es_ES |
dc.subject | método de elementos finitos | es_ES |
dc.subject | fuerzas de ortodoncia | es_ES |
dc.subject | estrés | es_ES |
dc.subject | MBT | es_ES |
dc.subject | Alexander | es_ES |
dc.subject | finite element method | es_ES |
dc.subject | orthodontic forces | es_ES |
dc.subject | stress | es_ES |
dc.subject | MBT | es_ES |
dc.subject | Alexander | es_ES |
dc.subject.classification | MEDICINA Y CIENCIAS DE LA SALUD | es_ES |
dc.title | Rango de fuerzas óptimas durante movimientos ortodóncicos simulados a través del Método de Elementos Finitos. | es_ES |
dc.type | Tesis de maestría | es_ES |
dc.creator.tid | curp | es_ES |
dc.contributor.tid | curp | es_ES |
dc.creator.identificador | SAOJ911111HGTLRH06 | es_ES |
dc.contributor.identificador | LOTO570324HGTZRS05 | es_ES |
dc.degree.name | Especialidad en Ortodoncia | es_ES |
dc.degree.department | Facultad de Medicina | es_ES |
dc.degree.level | Especialidad | es_ES |