dc.description En este trabajo de tesis se presenta un sistema cuantificador de fluorescencia que sugiere su utilización para el desarrollo de biosensores bacterianos que emiten fluorescencia. Este sistema está compuesto por un diodo emisor de luz (led) de color violeta, un filtro de excitación, un lente convergente y un fotodiodo BPW34 para la detección de la fluorescencia, un amplificador de transimpedancia que convierte la fotocorriente producida por el fotodiodo a una señal de voltaje. Se determinó la relación entre la fluorescencia y la concentración bacteriana modificada genéticamente con la proteína verde fluorescente mediante un modelo de crecimiento logístico. Los resultados del experimento demuestran que este sistema es sensible a la fluorescencia emitida por la proteína verde fluorescente (GFP) en respuesta a una dilución de 1:10 a 1:1000 de bacterias e.coli con GFP con tiempo de crecimiento de 16 horas y una fuente de excitación modulada a una frecuencia de 60 Hertz (hz) con una señal cuadrática, obteniendo un coeficiente de determinación (r. cuadrada) de 0.98. Mismos resultados sugieren el uso del sistema cuantificador de fluorescencia para el desarrollo de biosensores a partir de bacterias genéticamente modificadas. es_ES
dc.description In this thesis a fluorescence quantifier system is presented that suggests its use for the development of bacterial biosensors that emit fluorescence. This system consists of a violet-colored light emitting diode (LED), an excitation filter, a converging lens, a BPW34 photodiode for the detection of fluorescence, a transimpedance amplifier that converts the photocurrent produced by the photodiode to a voltage signal. The relationship between the fluorescence and the bacterial concentration genetically modified with the green fluorescent protein was determined by a logistic growth model. The results of the experiment show that this system is sensitive to the fluorescence emitted by the green fluorescent protein (GFP) in response to a dilution of 1: 1 to 1: 10000 of bacteria e.coli with GFP with a growth time of 16 hours and a source of excitation modulated at a frequency of 60 Hertz (hz) with a quadratic signal, obtaining a coefficient of determination (r. squared) of 0.98. The same results suggest the use of the fluorescence quantifier system for the development of biosensors from genetically modified bacteria. es_ES
dc.format Adobe PDF es_ES
dc.language.iso Español es_ES
dc.relation.requires Si es_ES
dc.rights Acceso Abierto es_ES
dc.subject Fluorescencia es_ES
dc.subject nitratos es_ES
dc.subject led es_ES
dc.subject fotodiodo es_ES
dc.subject.classification INGENIERÍA Y TECNOLOGÍA es_ES
dc.title Sistema cuantificador de fluorescencia para el desarrollo de biosensores de nitratos a partir de bacterias genéticamente modificadas. es_ES
dc.type Tesis de maestría es_ES
dc.creator.tid curp es_ES
dc.contributor.tid curp es_ES
dc.creator.identificador ROGR911007HMCMLL02 es_ES
dc.contributor.identificador COML830809HGTNDS00 es_ES
dc.degree.name Maestría en Ingeniería en Biosistemas es_ES
dc.degree.department Facultad de Ingeniería es_ES
dc.degree.level Maestría es_ES