Por favor, use este identificador para citar o enlazar este ítem: https://ri-ng.uaq.mx/handle/123456789/1202
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.rights.licensehttp://creativecommons.org/licenses/by-nd/4.0es_ES
dc.contributorLuis Miguel Contreras Medinaes_ES
dc.creatorRaul Romero Galindoes_ES
dc.date2018-06-
dc.date.accessioned2019-03-04T15:32:30Z-
dc.date.available2019-03-04T15:32:30Z-
dc.date.issued2018-06-
dc.identifierFluorescenciaes_ES
dc.identifiernitratoses_ES
dc.identifierledes_ES
dc.identifierfotodiodoes_ES
dc.identifier.urihttp://ri-ng.uaq.mx/handle/123456789/1202-
dc.descriptionEn este trabajo de tesis se presenta un sistema cuantificador de fluorescencia que sugiere su utilización para el desarrollo de biosensores bacterianos que emiten fluorescencia. Este sistema está compuesto por un diodo emisor de luz (led) de color violeta, un filtro de excitación, un lente convergente y un fotodiodo BPW34 para la detección de la fluorescencia, un amplificador de transimpedancia que convierte la fotocorriente producida por el fotodiodo a una señal de voltaje. Se determinó la relación entre la fluorescencia y la concentración bacteriana modificada genéticamente con la proteína verde fluorescente mediante un modelo de crecimiento logístico. Los resultados del experimento demuestran que este sistema es sensible a la fluorescencia emitida por la proteína verde fluorescente (GFP) en respuesta a una dilución de 1:10 a 1:1000 de bacterias e.coli con GFP con tiempo de crecimiento de 16 horas y una fuente de excitación modulada a una frecuencia de 60 Hertz (hz) con una señal cuadrática, obteniendo un coeficiente de determinación (r. cuadrada) de 0.98. Mismos resultados sugieren el uso del sistema cuantificador de fluorescencia para el desarrollo de biosensores a partir de bacterias genéticamente modificadas.es_ES
dc.descriptionIn this thesis a fluorescence quantifier system is presented that suggests its use for the development of bacterial biosensors that emit fluorescence. This system consists of a violet-colored light emitting diode (LED), an excitation filter, a converging lens, a BPW34 photodiode for the detection of fluorescence, a transimpedance amplifier that converts the photocurrent produced by the photodiode to a voltage signal. The relationship between the fluorescence and the bacterial concentration genetically modified with the green fluorescent protein was determined by a logistic growth model. The results of the experiment show that this system is sensitive to the fluorescence emitted by the green fluorescent protein (GFP) in response to a dilution of 1: 1 to 1: 10000 of bacteria e.coli with GFP with a growth time of 16 hours and a source of excitation modulated at a frequency of 60 Hertz (hz) with a quadratic signal, obtaining a coefficient of determination (r. squared) of 0.98. The same results suggest the use of the fluorescence quantifier system for the development of biosensors from genetically modified bacteria.es_ES
dc.formatAdobe PDFes_ES
dc.language.isoEspañoles_ES
dc.relation.requiresSies_ES
dc.rightsAcceso Abiertoes_ES
dc.subjectINGENIERÍA Y TECNOLOGÍAes_ES
dc.titleSistema cuantificador de fluorescencia para el desarrollo de biosensores de nitratos a partir de bacterias genéticamente modificadas.es_ES
dc.typeTesis de maestríaes_ES
dc.creator.tidcurpes_ES
dc.contributor.tidcurpes_ES
dc.creator.identificadorROGR911007HMCMLL02es_ES
dc.contributor.identificadorCOML830809HGTNDS00es_ES
dc.degree.nameMaestría en Ingeniería en Biosistemases_ES
dc.degree.departmentFacultad de Ingenieríaes_ES
dc.degree.levelMaestríaes_ES
Aparece en las colecciones: Maestría en Ingeniería en Biosistemas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
RI004292.pdf1.93 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.